NEW! Exclusive from Tenacious
A Battery CELL TESTER for 2 volt cells
FOR THE FIRST TIME YOU ARE ABLE TO “SEE” IF THERE IS PHYSICAL
DAMAGE TO THE INTERIOR OF YOU LEAD ACID BATTERY.
Rather than prematurely discarding your battery, costing your company a fortune and
adding to the already struggling environment, you are now able to know with 100%
certainty exactly what condition each cell is in. If sulfation is the only culprit causing your battery to behave less than expected we can fix that. If there is physical damage and you are able to remove and replace a single cell you are now able to detect damage even if the damage is at the bottom most point of the lead plate.
This is truly a must for anyone in the battery repair/restoration business or with more than one forklift-type battery!

This
is the DC 60B Battery Tester.
The DC 60B is a Load Tester specifically made for the forklift-type battery with
2-volt cells. By adjusting the toggle switches you can adjust the tester to 20A,
40A or 60A. (Simply take the aH for the battery and multiply by 0.10 then set
the tester for the proper amps)
A reading is taken for each cell after the battery is fully charged. Note each
measurement starting from the Pos. pole. (Numbering the cells will prevent any
errors). Also taking a density measurement for each cell is done.
The battery is now charged and discharged 3 times and a new reading is taken for
each cell – voltage and density.
If any cell is still showing a voltage reading below the average, even though
the density may be in the right range, that cell is physically damaged
internally and it must be replaced in order to get the full potential of the
battery.